Campuses and buildings

Water and power in a building, tenant by tenant.

Meters on the water lines and the low-tension panels, sensors on pumps and HVAC plant, and IoTyX to show who uses what, where water leaks and when a machine starts to drift.

In the field
Ilonnati controllers and sensors
On the screen
IoTyX: web, phone, control room
Illustration of a campus: two office towers with water tanks on their roofs, a cafeteria with a people counter over its door, a laundry block, a caged bank of gas cylinders and the pump that fills the tanks, with Ilonnati controllers.

On a typical site

  1. Rooftop tanks
  2. People counter
  3. Gas cylinder bank
  4. Sump pump
  5. Ilonnati controller

In short

Commercial buildings, malls, SEZs and IT parks draw water for washrooms, kitchens and HVAC cooling, and power for HVAC, pumps and lifts, and most of it reaches the owner as one bill. Ilonnati meters water by block, floor or tenant and measures power at the low-tension panels, with grid, solar and backup generator supply alongside. Pumps, motors and HVAC plant report vibration, temperature, voltage and current. IoTyX shows use per tenant and per system, flags leaks inside the building, and alerts on overcurrent, voltage deviation or a machine running outside its pattern. Tenants answer for what they use, and the owner has measured figures for green-building reporting.

Who it is for

  • Commercial building owners and managers
  • Malls and multiplexes
  • SEZs and IT parks
  • Facility management companies

Before and after

What changes

The same job, today and with Ilonnati.

  1. Today: Water arrives as one bill for the building, whoever used it. With Ilonnati: Meters by block, floor or tenant show who uses what, for billing by measured use.
  2. Today: A leak inside the building is found when a ceiling stains. With Ilonnati: Flow on a line that should be idle after hours raises a leak alert.
  3. Today: Water for HVAC cooling is topped up without being measured. With Ilonnati: Make-up water to the cooling plant is metered, so HVAC water use can be managed.
  4. Today: Power problems show up as a tripped panel or a failed motor. With Ilonnati: LT panels report overcurrent and voltage deviation, and machines report their condition.
  5. Today: Green-building figures are put together by hand from bills. With Ilonnati: Measured water and energy use, by system and tenant, is ready for reporting.

How it works

From the reading in the field to the action on the screen, and back.

  1. 01

    Meter the building

    Water meters go on the inlet and on each block, floor or tenant line; energy readings come from the LT panels and the generator.

  2. 02

    Watch the plant

    Pumps, motors and HVAC plant report vibration, temperature, voltage and current through a controller in the plant room.

  3. 03

    An after-hours leak

    Flow on a floor that should be idle after hours raises a leak alert for the facility team.

  4. 04

    Power out of line

    Voltage deviation or overcurrent on an LT panel alerts the electrical engineer, with the panel and the reading.

  5. 05

    Month-end by tenant

    Water and energy use per tenant come from meter readings, not from shares of the building’s bill.

  6. 06

    Reports

    Use by system, floor and tenant over time, for the owner’s sustainability and green-building reporting.

What is measured

Each reading reaches IoTyX through the Ilonnati controller beside the equipment.

ReadingWhat it tells you
Water per tenant or floorWho uses what, for billing and accountability
Cooling-plant make-up waterWhat HVAC cooling draws, and when it rises
After-hours flowA leak inside the building, when nothing should be drawing water
LT panel readingsOvercurrent, voltage deviation and power quality at each panel
Energy by sourceGrid, solar and generator supply, and use by system and division
Machine conditionVibration and temperature that point to a pump, motor or HVAC fault
Tank levelsUnderground and overhead tanks kept between their marks

The rules and programmes behind it

Public programmes and rules that ask for this kind of measurement. Each links to the body that publishes it.

  • 100 kW

    The Energy Conservation Building Code applies to buildings with a connected load of 100 kW or a contract demand of 120 kVA or more, and asks larger ones to meter HVAC, lighting and other services separately.

    ECBC 2017, as notified by Uttar Pradesh, 2018

Industries where it applies

Each industry page sets out its equipment, its rules and the other use cases that run there.

Questions buyers ask

Not answered here?

Ask about your own network, plant or campus. An engineer will reply.

Contact us
01Can it work with our building management system?

The wireless gateway speaks BACnet/IP, which many building management systems use, so readings can be passed between the two.

02Can tenants be billed for their own water?

Yes. Each tenant’s line is metered, and monthly use per tenant is reported from the readings.

03Which machines are monitored?

Pumps, motors and HVAC plant, for vibration, temperature, voltage and current. Readings that drift from a machine’s usual pattern raise an alert.

04Does it cover solar and generators?

Yes. Grid supply, solar, battery storage and backup generators are monitored together, with use set out by equipment and by division.