Contact us

Campuses and buildings

Tanks, meters and leaks in a gated community.

Level sensors in the sump and rooftop tanks, a controller on the pump, a meter at each flat’s inlet, and one screen for the association’s committee and facility manager.

In the field
Ilonnati controllers and sensors
On the screen
IoTyX: web, phone, control room
Illustration of a campus: two office towers with water tanks on their roofs, a cafeteria with a people counter over its door, a laundry block, a caged bank of gas cylinders and the pump that fills the tanks, with Ilonnati controllers.

On a typical site

  1. Rooftop tanks
  2. People counter
  3. Gas cylinder bank
  4. Sump pump
  5. Ilonnati controller

In short

A residential community stores water in an underground sump, filled from the municipal supply, a borewell or tankers, and pumps it to rooftop tanks on each block. Ilonnati puts level sensors in the sump and tanks and a controller on the pump, so tanks refill on their own level and the pump does not run the sump dry. An inlet meter records what is received, and a meter at each flat’s inlet records what the flat uses, for pay-per-use bills instead of a share by flat size. Flow that never stops inside a flat or block raises a leak alert, and drinking-water quality can be measured at the sump.

Who it is for

  • Residents’ welfare and apartment owners’ associations
  • Gated communities and high-rise societies
  • Row-house and villa communities
  • Facility managers running residential estates

Before and after

What changes

The same job, today and with Ilonnati.

  1. Today: The watchman starts the pump when someone calls about a dry tap. With Ilonnati: Each rooftop tank refills when it falls to its low mark and stops at its high mark.
  2. Today: Rooftop tanks overflow at night until someone hears the water. With Ilonnati: Tank overflow raises an alert on the committee’s and the facility manager’s phones.
  3. Today: Water charges are split by flat size, whatever each flat uses. With Ilonnati: A meter at each flat’s inlet records its use, for pay-per-use bills.
  4. Today: A running cistern or a leaking line goes on for weeks unnoticed. With Ilonnati: Flow that never stops, inside a flat or a block, raises a leak alert.
  5. Today: Nobody knows how much a tanker really delivered. With Ilonnati: A meter at the sump inlet records what each delivery, from mains, borewell or tanker, brings in.

How it works

From the reading in the field to the action on the screen, and back.

  1. 01

    Water comes in

    The inlet meter records what reaches the sump from the mains, the borewell or a tanker, and the sump level rises.

  2. 02

    A tank calls for water

    A rooftop tank falls to its low mark, and the controller starts the pump, as long as the sump has water to give.

  3. 03

    Full tank, pump stops

    At the tank’s high mark the pump stops. If the sump runs low first, the pump stops and an alert is raised.

  4. 04

    Each flat is metered

    Meters at each flat’s inlet report its use through the month, and each owner can see their own.

  5. 05

    A leak shows up

    A flat whose meter never comes to rest, even overnight, raises a leak alert for that flat.

  6. 06

    Bills from readings

    At month end, each flat’s metered use is the basis of its water bill, with the readings to back it.

What is measured

Each reading reaches IoTyX through the Ilonnati controller beside the equipment.

ReadingWhat it tells you
Sump levelWhat is stored below ground, and whether the pump can run
Rooftop tank levelWhen to refill each block’s tank, before it overflows or runs dry
Water receivedWhat the mains, borewell or tankers actually delivered
Use per flatEach flat’s consumption, for pay-per-use bills
Continuous flowA leak inside a flat or block that never lets the meter rest
TDS, pH and chlorineWhether drinking water from the sump is within its limits
Pump stateWhen each pump ran, and for how long

Industries where it applies

Each industry page sets out its equipment, its rules and the other use cases that run there.

Questions buyers ask

Not answered here?

Ask about your own network, plant or campus. An engineer will reply.

Contact us
01Do the tank sensors need cables?

No. The radar level sensor is wireless and runs on its own battery, around seven years when it reports once a day. A gateway on site gathers readings from more than 2,000 such sensors.

02Who sees what?

The committee and the facility manager see the whole community, and each owner can see their own flat. Only authorised people can start or stop a pump.

03Is drinking-water quality checked too?

It can be. pH, TDS and residual chlorine can be measured at the sump or the inlet, with an alert when a reading leaves its limit.

04Is it only for apartment blocks?

No. Row houses and villa communities use the same metering for each house’s use and leak alerts.

Tell us what you need to connect, monitor or control

An engineer will reply.