Contact us

Industries: Transport

For stations that serve drinking water.

Free drinking water at stations and bus stands is widely distrusted. Ilonnati measures it where passengers drink and shows the readings beside the tap.

Use cases
3 described below
To start
A pilot at one site

In the drawing

A platform canopy, a bus, a drinking-water point beside the platform, and an Ilonnati controller.

In short

Railway stations and bus stands provide free drinking water, but passengers often take it to be unsafe and buy bottled water instead, which adds to plastic waste, while packaged water itself is open to misbranding and adulteration. Ilonnati proposes a water-quality monitoring system with a display at the drinking-water point itself. Probes on the line feeding the taps measure pH, TDS, residual chlorine and turbidity, the display shows the latest readings, and the engineer responsible is alerted when one leaves its limit. Every station’s points appear on one map, with the history behind each display.

Why it is hard

The challenges

What makes transport hard to run without live measurement.

What Ilonnati runs here
  • Water passengers do not trust

    Free drinking water at stations and bus stands is perceived as unsafe, whatever its actual quality, so it goes unused.

  • Plastic waste

    Distrust of the tap drives demand for bottled water, and with it the plastic waste a station has to clear.

  • Misbranding and adulteration

    Packaged water carries its own risk of misbranding and adulteration, so bottled is not automatically safer.

  • Nothing at the point of use

    Quality is checked by sampling, if at all, and nothing at the tap tells a passenger what was found.

What Ilonnati measures and runs

Ilonnati controllers and sensors on the equipment, IoTyX on the screen.

  • Drinking-water quality

    pH, TDS, residual chlorine and turbidity, measured continuously on the line that feeds the taps.

  • Display at the tap

    A display beside the drinking-water point shows the latest readings and when they were taken.

  • Alerts

    A reading outside its limit alerts the station’s engineer by push notification, email and in the app.

  • Every station on a map

    All drinking-water points on one map, each with its readings and history, for the operator’s reports.

  • Supply tank level

    The level of the tank that feeds the taps, so it is refilled before the points run dry.

The rules and programmes behind it

Public programmes and rules that ask for this kind of measurement. Each links to the body that publishes it.

  • 0.2 mg/L

    IS 10500:2012 sets India’s drinking-water limits: pH 6.5 to 8.5, total dissolved solids 500 mg/L, nitrate 45 mg/L, fluoride 1.0 mg/L, and at least 0.2 mg/L of free residual chlorine.

    IS 10500:2012, Bureau of Indian Standards

Questions buyers ask

Not answered here?

Ask about your own network, plant or campus. An engineer will reply.

Contact us
01What does a passenger see?

A display beside the tap with the latest pH, TDS, residual chlorine and turbidity of the water, and the time of the reading.

02Is this in use at stations today?

Ilonnati proposes it for transport operators. A project would start with a pilot at a few drinking-water points before more stations are added.

03Can buses be monitored on the same platform?

Yes. IoTyX’s vehicle module shows each vehicle’s location, fuel use and performance, on the same platform as the stations.

Related industries

The same hardware and the same platform, set up for other sites in water and utilities and beyond.

Tell us what you need to connect, monitor or control

An engineer will reply.