Water and utilities
The water’s readings, shown at the tap.
At free drinking-water points in railway stations and bus stands, probes measure the water on the line that feeds the taps, and a display beside them shows the readings.
- In the field
- Ilonnati controllers and sensors
- On the screen
- IoTyX: web, phone, control room
On a typical site
- Elevated reservoir
- Pump set
- Motorised valve
- Meter at each connection
- Ilonnati controller
In short
Free drinking water at railway stations and bus stands is widely taken to be unsafe, so passengers buy bottled water instead, which adds to plastic waste, while packaged water has its own problems of misbranding and adulteration. Ilonnati’s approach is to measure the water where people drink it and show the result there. Probes on the line feeding the taps measure pH, TDS, residual chlorine and turbidity. The controller sends the readings to IoTyX and to a display at the drinking-water point. Station staff and engineers see every point on one screen, with an alert when a reading leaves its limit.
Who it is for
- Railway station and divisional engineering teams
- Road transport corporations and bus stand operators
- Municipal bodies running public drinking-water points
- Operators of water kiosks at transit hubs
Before and after
What changes
The same job, today and with Ilonnati.
- Today: Passengers cannot tell if tap water is safe, so many buy bottled water. With Ilonnati: A display at the tap shows the water’s latest readings and when they were taken.
- Today: Water is sampled now and then, and the results stay in an office file. With Ilonnati: pH, TDS, chlorine and turbidity are measured continuously on the line feeding the taps.
- Today: A problem with the supply is noticed when passengers complain. With Ilonnati: A reading outside its limit alerts the engineer responsible for that station.
- Today: Each station keeps its own records, if it keeps any. With Ilonnati: Every drinking-water point shows on one map with its history, for the operator’s reports.
How it works
From the reading in the field to the action on the screen, and back.
- 01
Fit on the supply line
Probes are fitted on the line that feeds the taps. The chlorine probe sits in a flow cell, with water flowing past it continuously.
- 02
Read and send
The controller beside the line reads each probe and sends the values to IoTyX, every ten seconds by default.
- 03
Shown at the tap
A display beside the drinking-water point shows the latest pH, TDS, residual chlorine and turbidity, and the time of the reading.
- 04
Out of limit
If chlorine falls too low or turbidity rises, the station’s engineer is alerted on the phone and in the control room.
- 05
Every station in one view
The operator sees all its drinking-water points on a map, with daily reports for each station.
What is measured
Each reading reaches IoTyX through the Ilonnati controller beside the equipment.
| Reading | What it tells you |
|---|---|
| pH | Whether the water is within its drinking range of 6.5 to 8.5 |
| TDS | Dissolved solids against the drinking-water limit of 500 mg/L |
| Residual chlorine | Whether the water is still disinfected when it reaches the tap |
| Turbidity | Whether the water is clear, and the filtering before it working |
| Time of reading | That the display shows the water as it is now, not an old result |
The rules and programmes behind it
Public programmes and rules that ask for this kind of measurement. Each links to the body that publishes it.
0.2 mg/L
IS 10500:2012 sets India’s drinking-water limits: pH 6.5 to 8.5, total dissolved solids 500 mg/L, nitrate 45 mg/L, fluoride 1.0 mg/L, and at least 0.2 mg/L of free residual chlorine.
IS 10500:2012, Bureau of Indian Standards
Industries where it applies
Each industry page sets out its equipment, its rules and the other use cases that run there.
Questions buyers ask
Ask about your own network, plant or campus. An engineer will reply.
Contact us01What does the display show?
The latest readings for the water at that point, pH, TDS, residual chlorine and turbidity, with the time they were taken.
02Who is alerted if a reading fails its limit?
The engineer or staff responsible for that station, by push notification, email and in the app, with the reading and the point it came from.
03Is this in use at stations today?
Ilonnati proposes it for transport operators. A project would start with a pilot at a few drinking-water points before more stations are added.
04Does it need anything at the tap besides the display?
A supply line to fit the probes on, and power for the controller and the display. Both are planned for each point before installation.
