Water and utilities
Water quality, measured where it changes.
Probes at the treatment works, the sumps, the reservoirs and out in distribution, read by a controller and shown in IoTyX, with an alert when a reading leaves its limit.
- In the field
- Ilonnati controllers and sensors
- On the screen
- IoTyX: web, phone, control room
On a typical site
- Elevated reservoir
- Pump set
- Motorised valve
- Meter at each connection
- Ilonnati controller
In short
Quality changes along the way: filtration sets turbidity, dosing sets chlorine, and chlorine decays between the reservoir and the far end of a network. Ilonnati measures pH, turbidity, residual chlorine, TDS and nitrate where those changes happen, from drinking water at the treatment works to wastewater leaving a plant. Digital probes are read by the controller beside them and report to IoTyX with everything else on the site. Each probe stores its own calibration, so it can be calibrated in a lab and swapped in the field. When a reading leaves its limit, such as low chlorine in distribution, the engineer responsible is alerted.
Who it is for
- Water boards and treatment works
- Town and rural water schemes
- Housing communities on borewell or tanker water
- Plants treating process water or effluent
- Operators of public drinking-water points
Before and after
What changes
The same job, today and with Ilonnati.
- Today: Samples go to a lab by hand, and results come back days later. With Ilonnati: Probes report continuously, and each reading reaches IoTyX with its time and place.
- Today: Chlorine is checked at the works, not where people draw water. With Ilonnati: Residual chlorine is measured at the reservoirs and in distribution, with an alert when it is low.
- Today: A probe drifts, and nobody knows when it was last calibrated. With Ilonnati: Probes store their calibration, and converters keep a dated log and remind when one is due.
- Today: A filter problem shows up as complaints about cloudy water. With Ilonnati: Turbidity is measured as water leaves treatment, so a filter problem shows at once.
- Today: Quality records are kept on paper, site by site. With Ilonnati: Every reading is kept with its place and time, for daily reports and audits.
How it works
From the reading in the field to the action on the screen, and back.
- 01
Choose the points
Measuring points are set where quality changes: after filtration, after dosing, at each reservoir and at the far end of the network.
- 02
Fit the probes
Digital probes are fitted at each point. The chlorine probe sits in a flow cell, with water flowing past it continuously.
- 03
Readings arrive
The controller reads each probe with its temperature, for compensation, and sends the values to IoTyX with the site’s other readings.
- 04
A limit is crossed
Residual chlorine at a reservoir falls below its limit, and the engineer gets a “less chlorine in distribution” alert.
- 05
Probes are kept true
A probe due for calibration is swapped for one calibrated in the lab; its calibration travels with it.
- 06
Daily summaries
Readings such as chlorine and pH can be reported with the day’s minimum, maximum and average, for the operations review.
What is measured
Each reading reaches IoTyX through the Ilonnati controller beside the equipment.
| Reading | What it tells you |
|---|---|
| pH | Whether water is within its drinking-water range of 6.5 to 8.5 |
| Turbidity | Whether filtration is working, and how clear the water is |
| Residual chlorine | Whether disinfection still holds at the reservoirs and the far end |
| TDS and conductivity | Dissolved solids against the drinking-water limit, and changes at the source |
| Nitrate | Contamination from run-off and sewage reaching the source |
| Redox (ORP) | Treatment and disinfection conditions, in supply and in effluent |
| Flow | The volume treated or discharged, alongside its quality |
The rules and programmes behind it
Public programmes and rules that ask for this kind of measurement. Each links to the body that publishes it.
0.2 mg/L
IS 10500:2012 sets India’s drinking-water limits: pH 6.5 to 8.5, total dissolved solids 500 mg/L, nitrate 45 mg/L, fluoride 1.0 mg/L, and at least 0.2 mg/L of free residual chlorine.
IS 10500:2012, Bureau of Indian Standards55 L
Jal Jeevan Mission counts a rural tap as functional only if it gives at least 55 litres per person per day, of BIS 10500 quality, on a regular schedule.
Jal Jeevan Mission, Functionality Assessment 202417
CPCB requires the 17 most polluting industry categories, with common effluent and sewage treatment plants, to stream effluent and emission readings to CPCB and the State Board in real time.
CPCB, real-time effluent monitoring guidelines, 2014
Industries where it applies
Each industry page sets out its equipment, its rules and the other use cases that run there.
Questions buyers ask
Ask about your own network, plant or campus. An engineer will reply.
Contact us01Which parameters can be measured?
pH, turbidity, residual chlorine, TDS and conductivity, and nitrate, each with temperature for compensation. Redox (ORP) is added where treatment or effluent needs it.
02How are the probes calibrated?
Calibration is stored in the probe, so a probe is calibrated in the lab and swapped on site without recalibrating there. The pH and redox converter keeps its last five calibrations, with dates, and can remind when the next is due.
03Does it cover wastewater as well as drinking water?
Yes. The same probes and controller measure treated effluent and process water, with limits set for each point.
04Can chlorine be sampled instead of measured continuously?
Yes. A sampling analyser takes a reading at a set interval, with low and high alarm points, and warns when its reagent is low or there is no sample.
05Can the public see the readings?
Yes. Readings can be shown on a display at the point of use, as proposed for drinking-water points at stations and bus stands.