Water and utilities

A city’s water network, zone by zone.

Bulk meters at each zone inlet, pressure on the mains, levels in every reservoir and controllers on the valves, so the engineer sees where the water goes and can act on it.

In the field
Ilonnati controllers and sensors
On the screen
IoTyX: web, phone, control room
Illustration of a town water system: treatment works, an elevated reservoir, a pump house, the main with motorised valves, homes with meters, and an Ilonnati controller beside each valve and pump.

On a typical site

  1. Elevated reservoir
  2. Pump set
  3. Motorised valve
  4. Meter at each connection
  5. Ilonnati controller

In short

A city network is a chain of service reservoirs and overhead tanks feeding zones through mains, branch lines and distribution lines, out to the tail-end connection. Ilonnati fits a controller beside each valve, pump and reservoir it is asked to run, a bulk meter at each zone inlet, pressure transmitters on the mains and meters at the connections. IoTyX puts every reading on a map of the network. Operators supply zones to a timetable, set valves part-way to share water with the tail end, and isolate a section when a main bursts. Water entering a zone is set against water reaching its consumers, so losses are traced to a zone.

Who it is for

  • Municipal corporations and water boards
  • Smart city water projects
  • Urban local bodies running their own supply
  • Contractors who operate and maintain a city network

Before and after

What changes

The same job, today and with Ilonnati.

  1. Today: Valves are turned by crews driving from one chamber to the next. With Ilonnati: Valves open, close or set part-way from the control room, and the controller confirms each move.
  2. Today: Reservoir levels are phoned in, or noticed when a tank overflows. With Ilonnati: Each reservoir and overhead tank reports its level as it changes, with an alert at its high mark.
  3. Today: Tail-end areas complain of low pressure, and nobody can say why. With Ilonnati: Pressure at zone boundaries and tail ends shows which zones are short of water.
  4. Today: Water lost between source and consumer is one estimate for the city. With Ilonnati: Bulk meters at each zone inlet, set against meters at the connections, trace losses to a zone.
  5. Today: A burst main shows up as a flooded road and a run of complaints. With Ilonnati: A sharp pressure drop alerts the engineer, who closes the valves around the main remotely.

How it works

From the reading in the field to the action on the screen, and back.

  1. 01

    Readings come in

    Each controller reports flow, pressure, level and valve position, every ten seconds by default, and at once whenever a valve moves.

  2. 02

    Zones are supplied

    At a zone’s supply slot its inlet valve opens. The bulk meter counts what enters, and the valve closes when the set quantity has gone in.

  3. 03

    The tail end is checked

    Pressure at the far end of the zone shows whether the last connections are served. If not, upstream valves are set part-way to share the supply.

  4. 04

    A main bursts

    Pressure on a main falls sharply, and the engineer for that zone is alerted on the phone and in the control room.

  5. 05

    The section is isolated

    The operator closes the valves around the section from the screen. Each valve reports as it moves and confirms when it is shut.

  6. 06

    The day’s reports

    Supply by zone, schedule deviations, overflow and leakage reports, and the status of each hydraulic zone, ready for the morning review.

What is measured

Each reading reaches IoTyX through the Ilonnati controller beside the equipment.

ReadingWhat it tells you
Zone inflowHow much water each zone receives, and when, against its schedule
Consumption at connectionsWhat reaches consumers, to set against the zone’s inflow
Main and tail-end pressureWhether the far end is served, and where a main may have burst
Reservoir and tank levelWhat is stored, before a tank overflows or runs dry
Valve positionWhere each valve stands, 0 to 100% open, as it moves
Residual chlorineWhether disinfection still holds at the reservoirs and in distribution
Pump stateWhether each pump runs when it should, and for how long

The rules and programmes behind it

Public programmes and rules that ask for this kind of measurement. Each links to the body that publishes it.

Industries where it applies

Each industry page sets out its equipment, its rules and the other use cases that run there.

Questions buyers ask

Not answered here?

Ask about your own network, plant or campus. An engineer will reply.

Contact us
01Do valves or pipes have to be replaced?

No pipe is replaced. A motorised actuator is fitted to each valve in working order and a controller is placed beside it; a seized valve is repaired first.

02How often do readings arrive?

By default each controller reports every ten seconds, and the interval is set per site. It also reports at once after every command and whenever a valve moves by more than 1%.

03Can a valve be set part-way?

Yes, anywhere from 0 to 100% open. Position is measured against the valve’s own learned fully closed and fully open points.

04What if part of the network already runs on SCADA?

Say so at the start. The pilot is then planned around what the existing system already runs.

05What does the control room see?

The network on a map with live readings and alerts, and reports on supply by zone, schedule deviation, reservoirs, overflow, leakage and the status of each hydraulic zone.

Tell us what you need to connect, monitor or control

An engineer will reply.