Contact us

Water and utilities

Leaks and theft, traced to a zone.

Meters at each zone inlet and at the connections, pressure on the mains, and an alert when flow or pressure does what it should not, so the engineer knows which zone to search.

In the field
Ilonnati controllers and sensors
On the screen
IoTyX: web, phone, control room
Illustration of a town water system: treatment works, an elevated reservoir, a pump house, the main with motorised valves, homes with meters, and an Ilonnati controller beside each valve and pump.

On a typical site

  1. Actuator on an existing valve
  2. Ilonnati controller

In short

Water leaves a network through bursts, slow leaks, illegal connections and meters that have been tampered with, and each shows in the readings before it shows on the road. Ilonnati meters what enters each zone and what reaches each connection, measures pressure on the mains, and raises an alert when flow or pressure moves outside its pattern: flow into a zone that should be shut, a sharp fall in pressure, or a meter reporting a leak or a tamper event. IoTyX places each alert on the network map, so the engineer knows which zone to search, and the valves around a burst can be closed from the control room.

Who it is for

  • Water boards and municipal corporations
  • Non-revenue water programmes
  • Town and rural water schemes
  • Housing communities with their own network
  • Campuses and industrial sites with their own mains

Before and after

What changes

The same job, today and with Ilonnati.

  1. Today: A leak is found when water surfaces on the road or a consumer complains. With Ilonnati: Flow or pressure outside its usual pattern raises an alert as it happens.
  2. Today: Losses are estimated for the whole network, with no way to say where. With Ilonnati: Inflow at each zone set against use at its connections shows which zone is losing water.
  3. Today: Illegal connections are found by chance, or by a tip-off. With Ilonnati: Water that enters a zone but reaches no metered connection shows where to look.
  4. Today: A tampered meter under-reads for months before anyone checks it. With Ilonnati: Meters report tampering when it happens, and mechanical bulk meters are unaffected by magnets.
  5. Today: A burst main runs until a crew has reached each valve by hand. With Ilonnati: The valves around the burst are closed from the control room while the crew is on its way.

How it works

From the reading in the field to the action on the screen, and back.

  1. 01

    Meter the boundaries

    Bulk meters go at each zone inlet and meters at the connections, so every zone has a figure for water in and water used.

  2. 02

    Watch the pressure

    Pressure transmitters on the mains report continuously. A sharp fall marks a likely burst on that main.

  3. 03

    Flag the pattern

    Flow into a zone outside its supply hours, more than a zone should draw, or a meter’s leak or tamper event raises an alert.

  4. 04

    Place it on the map

    Each alert appears on the network map at its meter or main, with the readings around it.

  5. 05

    Isolate and repair

    The operator closes the valves around the section from the screen, and the crew goes to the zone the readings point to.

  6. 06

    Check the repair

    Leakage reports by zone show whether the loss has stopped once the repair is done.

What is measured

Each reading reaches IoTyX through the Ilonnati controller beside the equipment.

ReadingWhat it tells you
Zone inflowWhat each zone receives: the first half of any loss calculation
Consumption at connectionsWhat reaches consumers; the gap to inflow is the zone’s loss
Main pressureA sharp fall points to a burst on that main
Flow outside supply hoursWater drawn when the zone should be shut: a leak or an illegal draw
Meter eventsA leak, a burst or tampering, flagged by the meter as it happens
Valve positionWhich valves are shut, so a section stays isolated until it is repaired

The rules and programmes behind it

Public programmes and rules that ask for this kind of measurement. Each links to the body that publishes it.

Industries where it applies

Each industry page sets out its equipment, its rules and the other use cases that run there.

Questions buyers ask

Not answered here?

Ask about your own network, plant or campus. An engineer will reply.

Contact us
01Does it find the exact pipe?

It narrows the search. Meters and pressure points divide the network into zones and sections, an alert shows which one is losing water, and the crew searches there. The more points measured, the smaller the area to search.

02What does theft look like in the readings?

Water that enters a zone but reaches no metered connection, flow outside the zone’s supply hours, and meters that report tampering. Each is raised as an alert for the zone’s engineer.

03Does it work where supply is intermittent?

Yes. Each zone has known supply hours, so flow into it outside them is flagged on its own, as a sign of a leak or an unauthorised draw.

04Does the same approach work for power and gas?

Yes. Measuring what enters a network against what reaches its users applies to power and gas lines as well, and IoTyX monitors both.

Tell us what you need to connect, monitor or control

An engineer will reply.