Contact us

Environment and agriculture

Air quality, measured where people breathe it.

Stations at junctions, plant boundaries and mine edges measure particulates, gases and noise, and IoTyX puts each reading on a map with its trend.

In the field
Ilonnati controllers and sensors
On the screen
IoTyX: web, phone, control room
Illustration of environmental monitoring and farming: an air-quality station, a buoy and a level gauge on a river, fields with soil sensors and a drip main, a polyhouse, and a drone over the forest, with Ilonnati controllers.

On a typical site

  1. Air-quality station
  2. River buoy
  3. Soil sensors
  4. Flood level gauge
  5. Ilonnati controller

In short

An outdoor station takes up to eight air readings at once, chosen for the site from PM2.5, PM10, NO₂, SO₂, CO, O₃, CO₂ and total VOCs, with temperature, humidity and air pressure alongside. It reports as often as every minute and keeps 1-minute, 1-hour and 24-hour averages, to compare with the standards. Noise is measured with it. IoTyX places every station on a GIS map, so hotspots show where they are, and alerts the officer for an area when a reading crosses its threshold. AI forecasts the air quality index, and a digital twin simulates city-wide air quality scenarios.

Who it is for

  • Pollution control boards
  • Municipal corporations and Smart City companies
  • Industrial plants, at their boundary
  • Mining sites
  • Tunnel and underground space operators
  • Large campuses

Before and after

What changes

The same job, today and with Ilonnati.

  1. Today: Air is sampled at a few points, and the results arrive days later. With Ilonnati: Each station reports as often as every minute, with 1-hour and 24-hour averages kept.
  2. Today: A pollution hotspot is known by complaint or by guesswork. With Ilonnati: Every station sits on a map, so the hotspots show where they are.
  3. Today: A high reading turns up in the next report, after the episode has passed. With Ilonnati: A reading over its threshold alerts the officer for that area as it happens.
  4. Today: Stations go where there is mains power. With Ilonnati: A solar-powered station runs at least 96 hours without sun, so it can go where the air needs measuring.
  5. Today: Plans are made from past readings alone. With Ilonnati: AI forecasts the air quality index, and a digital twin tests city-wide scenarios first.

How it works

From the reading in the field to the action on the screen, and back.

  1. 01

    Stations placed

    Stations go on walls, roofs, poles or the ground at junctions, boundaries and tunnels, on mains or solar power, sited with the authority.

  2. 02

    Readings every minute

    Particulates, gases, temperature, humidity and pressure reach IoTyX as they are taken, with 1-minute, 1-hour and 24-hour averages.

  3. 03

    Hotspots on the map

    Each station shows on the map with its latest readings and trend, so the worst corners of the city or site stand out.

  4. 04

    A threshold is crossed

    PM2.5 at a junction rises above its limit at rush hour, and the officer for that area is alerted by push, email and in the app.

  5. 05

    Forecast and simulate

    AI forecasts the air quality index from the readings, and a digital twin simulates city-wide air quality scenarios before measures are taken.

  6. 06

    Reports kept

    Daily, weekly and monthly reports by station, with every reading kept with its place and time.

What is measured

Each reading reaches IoTyX through the Ilonnati controller beside the equipment.

ReadingWhat it tells you
PM2.5Fine particles from combustion and dust, 0–1,000 µg/m³
PM10Coarser dust from roads, building work and haulage, 0–1,000 µg/m³
Nitrogen dioxide (NO₂)Mostly from exhausts and burning fuel, so it follows the traffic
Sulphur dioxide (SO₂)From burning coal and fuel oil; it points to industrial sources
Carbon monoxide and ozoneCO close to traffic; O₃ formed in sunlight from other pollutants
CO₂ and total VOCsCombustion and stale air in enclosed spaces; solvents and fuel vapour
NoiseSound level by place and hour, day against night
Temperature, humidity, pressureThe weather each reading was taken in, so it is read correctly

The rules and programmes behind it

Public programmes and rules that ask for this kind of measurement. Each links to the body that publishes it.

Industries where it applies

Each industry page sets out its equipment, its rules and the other use cases that run there.

Questions buyers ask

Not answered here?

Ask about your own network, plant or campus. An engineer will reply.

Contact us
01Which readings does a station take?

Up to eight at once, chosen for the site from PM2.5, PM10, CO, NO₂, SO₂, O₃, CO₂ and total VOCs, with temperature, humidity and air pressure. Noise is measured alongside.

02How often does it report?

From every minute to once a day, set per station; every minute by default. It also keeps 1-minute, 1-hour and 24-hour averages, to compare with the standards.

03Does a station need mains power?

No. It runs on mains through an adapter, or on solar power, and the solar version keeps running for at least 96 hours without sun.

04Where can a station be mounted?

On a wall, a roof, a pole or the ground, in the open air, in a tunnel or in an underground space.

05What do the forecast and the digital twin add?

AI forecasts the air quality index from the readings, and a digital twin of the city simulates air quality scenarios across it, so measures can be weighed before they are taken.

Tell us what you need to connect, monitor or control

An engineer will reply.