Industries: Iron and steel
The water a steel plant runs on, measured.
Flow and quality on the cooling circuits and process lines of a steel plant, and its motors, energy and gas on the same platform.
- Use cases
- 6 described below
- To start
- A pilot at one site
In the drawing
A blast furnace, its stoves and a chimney, a rolling shed, a drive motor, and an Ilonnati controller.
In short
Most of the water a steel plant uses is for cooling, to protect equipment and to improve working conditions. A smaller but considerable share is process water: it concentrates iron ore, cleans coke-oven gas, quenches coke and slag and descales steel. Where water touches the steel, as in rolling, it must be of better quality than the rest. Ilonnati measures the quantity of water on each circuit and line, and its quality where quality matters, with both customised to the plant. The same platform watches the plant’s motors and pumps, its energy use and its gas.
Why it is hard
The challenges
What makes iron and steel hard to run without live measurement.
What Ilonnati runs hereWater used in many places
Cooling circuits, process lines, boiler feed and service water draw on the same supply, and without separate meters nobody can say which uses what.
Quality where water meets steel
In rolling, water touches the steel being processed, and poorer water there means changes to equipment and to operating practice.
Scale and corrosion
Disinfection and the control of scale and corrosion are the usual treatments, and both depend on knowing the water’s condition.
Heavy machines, heavy loads
Pumps, fans and mill drives run under heavy load, and a failure on one can stop a whole line.
What Ilonnati measures and runs
Ilonnati controllers and sensors on the equipment, IoTyX on the screen.
Cooling water
Flow on each cooling circuit, with conductivity and pH to show when salts and scale are building up.
Process water
Quantity drawn for ore concentration, gas cleaning, quenching and descaling, line by line.
Rolling mill water
Quality measured where water touches the steel, so a change is seen before it affects the product.
Effluent
Flow and quality where water leaves the plant, checked against the norms that apply.
Motors and pumps
Vibration, temperature, voltage and current on the drives the plant cannot afford to lose.
Energy and gas
Power by source and by machine, and gas flow and consumption by department and equipment.
Use cases
Each has a page of its own: the situation, how it works and what is measured.
Process water and effluentFresh, cooling and process water measured where it is drawn and used, and effluent checked before it leaves.MeasuresIntake flow, Cooling and process flow, pH
Predictive maintenanceVibration, temperature, voltage and current on pumps, motors and HVAC, so a fault is found before the machine stops.MeasuresVibration, Temperature, Voltage
Energy managementGrid, solar, wind, battery and generator supply in one view, down to the LT panel and each machine.MeasuresSupply by source, Voltage, Current
Gas managementGas flow and consumption measured as it is used, with reports by department and by piece of equipment.MeasuresGas flow, Consumption by department, Consumption by equipment
Industrial safety monitoringGas leaks, vibration, noise, air quality and worker exposure measured across a plant, with alerts at the thresholds.MeasuresGas leaks, Noise, Vibration
Site digital twinA live replica of the site, every asset on a map with its maintenance history, and inspections by 360° walk-through.MeasuresAsset location, Maintenance history, Asset condition
The rules and programmes behind it
Public programmes and rules that ask for this kind of measurement. Each links to the body that publishes it.
1,333
Under the PAT scheme, 1,333 large energy users in 13 sectors have energy-saving targets; in 2022–23 they saved 25.77 million tonnes of oil equivalent.
PAT scheme, PIB, Ministry of Power, 29 July 202417
CPCB requires the 17 most polluting industry categories, with common effluent and sewage treatment plants, to stream effluent and emission readings to CPCB and the State Board in real time.
CPCB, real-time effluent monitoring guidelines, 2014Any project that needs a CGWA groundwater permit must fit a digital flow meter with telemetry on every borewell.
CGWA guidelines, 2020, Ministry of Jal Shakti
Questions buyers ask
Ask about your own network, plant or campus. An engineer will reply.
Contact us01What can be measured in a steel plant’s water system?
The quantity of water on each cooling circuit and process line, and its quality where quality matters, such as pH, conductivity and turbidity, including the effluent that leaves the plant.
02Is it a standard system?
No. Quantity measurement and quality monitoring are customised to the plant: which lines are metered and which parameters are measured is decided with its engineers.
03Can meters already in the line be used?
Yes. Where a mechanical meter is already fitted, a clip-on pulse sensor lets it report without being replaced.
Related industries
The same hardware and the same platform, set up for other sites in industry and energy and beyond.
Industry and energyCementKilns, crushers, conveyors and mills watched as one plant through a digital twin, with energy measured per machine.
Industry and energyPharmaceuticalsThe grades of water a pharmaceutical plant depends on, measured continuously, with its utilities watched alongside.
Industry and energyPower and energyFresh water for cooling measured and kept to need, and every source of power on a site monitored down to the panel.
Industry and energyChemicals and fertilisersWater drawn, used and discharged, effluent checked against its norms, and gas and safety watched across the plant.