Industries: Chemicals and fertilisers
A fertiliser plant’s water footprint, measured.
Water measured from the borewell to the outfall, effluent monitored against the norms that apply, and gas leaks and worker exposure watched across the plant.
- Use cases
- 6 described below
- To start
- A pilot at one site
In the drawing
Storage tanks, a horizontal vessel, a pipe rack, a flare stack, and an Ilonnati controller.
In short
Making fertiliser is a moderately water-intensive process, and many plants draw much of their water from the ground. The wastewater from a urea plant can carry ammoniacal and Kjeldahl nitrogen and cyanide, which pollute ground and surface water if they are not treated. Ilonnati measures the water a plant draws and uses, to reduce its water footprint, and monitors its effluent to help the plant stay within the discharge norms that apply, including those for nitrogen and cyanide. Across the site, detectors and wearables watch for gas leaks and worker exposure, and gas flow, energy and critical machines are monitored on the same platform.
Why it is hard
The challenges
What makes chemicals and fertilisers hard to run without live measurement.
What Ilonnati runs hereReliance on groundwater
Many plants draw their water from borewells, and without metering, how much is drawn is a guess.
Nitrogen and cyanide in wastewater
Urea plant wastewater can carry ammoniacal and Kjeldahl nitrogen and cyanide, which pollute ground and surface water if not treated.
Discharge norms
Effluent must meet the discharge norms that apply to the plant, and hand sampling leaves long gaps between results.
Hazardous gases
Process gases and stored chemicals can leak, and a leak found by smell or on a round is found late.
What Ilonnati measures and runs
Ilonnati controllers and sensors on the equipment, IoTyX on the screen.
Water drawn
Flow from each borewell and source, so the plant knows what it takes from the ground.
Process and cooling water
What each unit and cooling circuit uses, line by line, for the plant’s water balance.
Effluent
Flow and quality where wastewater leaves the plant, checked against its norms, with an alert before a limit is crossed.
Gas leaks and air
Detectors for leaks near storage and process units, and air quality where people work.
Worker exposure
Wearables that measure what each person is exposed to through the shift.
Gas and energy use
Gas flow and consumption by unit and equipment, and power by source and by machine.
Use cases
Each has a page of its own: the situation, how it works and what is measured.
Process water and effluentFresh, cooling and process water measured where it is drawn and used, and effluent checked before it leaves.MeasuresIntake flow, Cooling and process flow, pH
Industrial safety monitoringGas leaks, vibration, noise, air quality and worker exposure measured across a plant, with alerts at the thresholds.MeasuresGas leaks, Noise, Vibration
Gas managementGas flow and consumption measured as it is used, with reports by department and by piece of equipment.MeasuresGas flow, Consumption by department, Consumption by equipment
Predictive maintenanceVibration, temperature, voltage and current on pumps, motors and HVAC, so a fault is found before the machine stops.MeasuresVibration, Temperature, Voltage
Energy managementGrid, solar, wind, battery and generator supply in one view, down to the LT panel and each machine.MeasuresSupply by source, Voltage, Current
Environmental complianceAir, water and noise measured around the clock at a site, each reading checked against its limit as it arrives.MeasuresPM2.5 and PM10, NO₂, SO₂ and CO, Noise
The rules and programmes behind it
Public programmes and rules that ask for this kind of measurement. Each links to the body that publishes it.
17
CPCB requires the 17 most polluting industry categories, with common effluent and sewage treatment plants, to stream effluent and emission readings to CPCB and the State Board in real time.
CPCB, real-time effluent monitoring guidelines, 201485%
An industry must keep 85% of its monitoring data reaching CPCB every month, for every station and parameter.
CPCB, policy for real-time data collectionAny project that needs a CGWA groundwater permit must fit a digital flow meter with telemetry on every borewell.
CGWA guidelines, 2020, Ministry of Jal Shakti
Questions buyers ask
Ask about your own network, plant or campus. An engineer will reply.
Contact us01What does it measure in a fertiliser plant’s water?
The quantity drawn from each source and used by each unit, and the quality of effluent where it leaves the plant. Effluent parameters are chosen for the norms the plant must meet.
02Does it replace the plant’s laboratory sampling?
No. Continuous readings show what happens between samples; the sampling and tests the plant carries out go on as before.
03Can safety monitoring run on the same platform?
Yes. Gas leaks, noise, air quality and worker exposure are measured across the site and shown with the water and energy readings, each with its own alerts.
Related industries
The same hardware and the same platform, set up for other sites in industry and energy and beyond.
Industry and energyCementKilns, crushers, conveyors and mills watched as one plant through a digital twin, with energy measured per machine.
Industry and energyPharmaceuticalsThe grades of water a pharmaceutical plant depends on, measured continuously, with its utilities watched alongside.
Industry and energyIron and steelCooling and process water measured by quantity and quality, with the plant’s motors, energy and gas watched alongside.
Industry and energyPower and energyFresh water for cooling measured and kept to need, and every source of power on a site monitored down to the panel.