Industries: Cement
A cement plant, from crusher to kiln, on one screen.
Sensors on the machines that keep a cement line running, a digital twin to watch and test the plant remotely, and energy measured where the plant uses most of it.
- Use cases
- 6 described below
- To start
- A pilot at one site
On a typical site
- Rotary kiln
- Drive motor
- Substation
- Solar and wind
- Ilonnati controller
In short
A cement plant is one long chain. Limestone is crushed and conveyed, ground in the raw mill, burned in the kiln into clinker, and the clinker ground with gypsum into cement; a stop at any machine holds up everything after it. Ilonnati builds a digital twin of the plant from sensors on its kilns, crushers and conveyors, so engineers watch it remotely, see a failure coming and try process changes on the replica first. Energy is measured per machine, including the mills and fans, and dust and worker safety are measured across the site.
Why it is hard
The challenges
What makes cement hard to run without live measurement.
What Ilonnati runs hereUnplanned stops
A kiln, crusher or conveyor that fails without warning stops the line behind it, and bringing a kiln back up costs time, fuel and output.
Maintenance by calendar
Machines are serviced on a schedule or after they fail, not on their condition, so some are opened too early and others too late.
Expertise far from the plant
Plants sit near their quarries, often far from cities, so diagnosing a fault can wait for a specialist to travel.
A power-hungry process
Grinding and burning use large amounts of power and fuel, and without per-machine figures it is hard to say where to save.
Changes that carry risk
Trying a new setting on a running kiln puts output and quality at risk, so changes are made slowly, or not at all.
What Ilonnati measures and runs
Ilonnati controllers and sensors on the equipment, IoTyX on the screen.
Kiln
Vibration and temperature on the kiln drive, mirrored on the digital twin, so a developing fault is seen before production stops.
Crushers
Vibration, temperature and motor current on the crushers that feed the line, where shocks and overloads are part of the job.
Conveyors
Drive motors and gearboxes on the belts that carry material between stages, watched for the signs that come before a stop.
Mills and fans
Power, current and vibration on the motors that drive the mills and fans, among the plant’s largest.
Energy per tonne
Energy from the grid, solar or the plant’s own generators, set against output, to give the power used per tonne of cement.
Dust and site safety
PM2.5 and PM10 at the plant boundary, with gas, noise and worker exposure measured where people work.
Use cases
Each has a page of its own: the situation, how it works and what is measured.
Cement plant digital twinKilns, crushers and conveyors mirrored as a live replica, watched and diagnosed from anywhere.MeasuresVibration, Temperature, Voltage and current
Predictive maintenanceVibration, temperature, voltage and current on pumps, motors and HVAC, so a fault is found before the machine stops.MeasuresVibration, Temperature, Voltage
Energy managementGrid, solar, wind, battery and generator supply in one view, down to the LT panel and each machine.MeasuresSupply by source, Voltage, Current
Industrial safety monitoringGas leaks, vibration, noise, air quality and worker exposure measured across a plant, with alerts at the thresholds.MeasuresGas leaks, Noise, Vibration
Site digital twinA live replica of the site, every asset on a map with its maintenance history, and inspections by 360° walk-through.MeasuresAsset location, Maintenance history, Asset condition
Air quality monitoringOutdoor stations for particulates, gases and noise, reporting as often as every minute to a map.MeasuresPM2.5, PM10, Nitrogen dioxide (NO₂)
The rules and programmes behind it
Public programmes and rules that ask for this kind of measurement. Each links to the body that publishes it.
1,333
Under the PAT scheme, 1,333 large energy users in 13 sectors have energy-saving targets; in 2022–23 they saved 25.77 million tonnes of oil equivalent.
PAT scheme, PIB, Ministry of Power, 29 July 202417
CPCB requires the 17 most polluting industry categories, with common effluent and sewage treatment plants, to stream effluent and emission readings to CPCB and the State Board in real time.
CPCB, real-time effluent monitoring guidelines, 2014Any project that needs a CGWA groundwater permit must fit a digital flow meter with telemetry on every borewell.
CGWA guidelines, 2020, Ministry of Jal Shakti
Questions buyers ask
Ask about your own network, plant or campus. An engineer will reply.
Contact us01What can be monitored in a cement plant?
Kilns, crushers and conveyors, and the motors that drive the mills and fans: their vibration, temperature, voltage and current, with the energy each machine uses.
02What does the digital twin add?
A live replica of the plant that engineers can open from anywhere. It shows where readings are drifting, supports remote diagnostics, and lets process changes be tried virtually before they are made.
03Can it start with one line?
Yes. A pilot can start with the machines whose failure costs the most, such as the kiln drive or the main crusher, and grow from there.
04Does it work with the plant’s control system?
It is designed around what the plant already runs. What IoTyX watches, and what it may switch, is agreed for each project.
Related industries
The same hardware and the same platform, set up for other sites in industry and energy and beyond.
Industry and energyPharmaceuticalsThe grades of water a pharmaceutical plant depends on, measured continuously, with its utilities watched alongside.
Industry and energyIron and steelCooling and process water measured by quantity and quality, with the plant’s motors, energy and gas watched alongside.
Industry and energyPower and energyFresh water for cooling measured and kept to need, and every source of power on a site monitored down to the panel.
Industry and energyChemicals and fertilisersWater drawn, used and discharged, effluent checked against its norms, and gas and safety watched across the plant.
