Industry and energy
Every litre a plant draws, uses and discharges.
Flow meters on intakes, cooling circuits and process lines, quality probes where water is used and discharged, and IoTyX to show the plant’s water balance and its effluent against the norms.
- In the field
- Ilonnati controllers and sensors
- On the screen
- IoTyX: web, phone, control room
On a typical site
- Rotary kiln
- Drive motor
- Substation
- Solar and wind
- Ilonnati controller
In short
Heavy industry draws large volumes of fresh water and returns much of it as effluent. In a steel plant most of it cools equipment, and the rest concentrates ore, cleans coke-oven gas, quenches coke and slag and descales steel. A thermal power station depends on fresh water for cooling. A urea plant’s wastewater can carry ammoniacal nitrogen and cyanide. Ilonnati measures the quantity of fresh, cooling and process water at each point that matters, and its quality where quality counts. Effluent is monitored where it leaves the site and checked against the norms that apply, with an alert before a limit is crossed.
Who it is for
- Iron and steel plants
- Thermal power stations
- Fertiliser and chemical plants
- Pharmaceutical and other process plants
- Environment and utilities managers
Before and after
What changes
The same job, today and with Ilonnati.
- Today: Fresh water drawn is estimated from pump hours or a single meter. With Ilonnati: Intake from each source is metered continuously, as it is drawn.
- Today: Cooling circuits and process lines share water nobody has measured. With Ilonnati: Each circuit and line is metered, so the plant’s water balance closes.
- Today: Effluent is sampled by hand, and the result comes back days later. With Ilonnati: Effluent is measured where it leaves the site, with an alert before a limit is crossed.
- Today: Water quality on a rolling or rinse line is checked when the product suffers. With Ilonnati: Quality is measured continuously where water touches the product.
- Today: Cooling make-up water is topped up by habit. With Ilonnati: Make-up is metered, and its valve can be set from the control room.
How it works
From the reading in the field to the action on the screen, and back.
- 01
List the water
Each source, cooling circuit, process line and discharge point is listed with the plant’s engineers, with the meter or probe each one needs.
- 02
Meters and probes
Flow meters go on intakes and process lines; pH, conductivity and turbidity probes where quality matters and at the outfall.
- 03
The balance
IoTyX sets what was drawn against what each process used and what left the site, day by day.
- 04
Effluent watched
Discharge quality is checked continuously against the plant’s limits, and the environment team sees it as it changes.
- 05
A reading nears its limit
Effluent pH moves towards its limit, the alert goes out, and the treatment plant is adjusted before the water leaves.
- 06
Records for review
Every reading is kept with its time and place, and daily and monthly reports support the plant’s compliance reporting.
What is measured
Each reading reaches IoTyX through the Ilonnati controller beside the equipment.
| Reading | What it tells you |
|---|---|
| Intake flow | How much fresh water each source supplies, and when |
| Cooling and process flow | What each circuit and line draws and returns |
| pH | Acid or alkaline drift in process water and effluent |
| Conductivity and dissolved solids | Salts building up in cooling water, and carried out in effluent |
| Turbidity | Suspended solids in process water and discharge |
| Effluent flow | What leaves the site, for the water balance and the plant’s reports |
| Line pressure | Lines and vessels kept within their limits |
The rules and programmes behind it
Public programmes and rules that ask for this kind of measurement. Each links to the body that publishes it.
17
CPCB requires the 17 most polluting industry categories, with common effluent and sewage treatment plants, to stream effluent and emission readings to CPCB and the State Board in real time.
CPCB, real-time effluent monitoring guidelines, 201485%
An industry must keep 85% of its monitoring data reaching CPCB every month, for every station and parameter.
CPCB, policy for real-time data collectionAny project that needs a CGWA groundwater permit must fit a digital flow meter with telemetry on every borewell.
CGWA guidelines, 2020, Ministry of Jal Shakti500 m³
A project drawing more than 500 m³ of groundwater a day needs two piezometers, one of them with a telemetered water level recorder.
CGWA guidelines, 2020, Ministry of Jal Shakti
Industries where it applies
Each industry page sets out its equipment, its rules and the other use cases that run there.
Questions buyers ask
Ask about your own network, plant or campus. An engineer will reply.
Contact us01Which effluent parameters can be measured?
pH, conductivity and dissolved solids, turbidity and flow are measured continuously. Ilonnati’s water quality monitoring for industrial wastewater also covers BOD, COD and heavy metals; which parameters a plant measures online is agreed against its own norms.
02Does it replace the laboratory?
No. Continuous readings show what happens between laboratory tests; the plant’s sampling and laboratory work go on as before.
03Can meters already in the line be used?
Yes. A mechanical meter already in the line can report through a clip-on pulse sensor, without being replaced. New lines can take an electromagnetic meter, which has no moving parts.
04Which limits are the readings checked against?
The ones that apply to the plant, set as thresholds in IoTyX for each parameter at each point.