Industry and energy
Where the energy goes, machine by machine.
Every source of power on a site, from the grid to the generator, measured in one place, down to the low-tension panels and the machines they feed, and set against what was produced.
- In the field
- Ilonnati controllers and sensors
- On the screen
- IoTyX: web, phone, control room
On a typical site
- Rotary kiln
- Drive motor
- Substation
- Solar and wind
- Ilonnati controller
In short
A plant’s power usually arrives as one bill and one meter reading. Ilonnati measures it by source, from the grid, solar, wind, battery storage and backup generators, and by where it goes: each low-tension (LT) panel, each division and each major machine. Panel readings show overcurrent, voltage deviation and power quality as they happen. IoTyX sets energy against output to give the energy used per unit produced, and shows which machines draw more than their rated capacity suggests. Alerts are set by policy, for a threshold that is crossed or a trend that drifts, so a problem is dealt with in the week it starts.
Who it is for
- Energy managers and plant engineers
- Manufacturing and process plants
- Sites with solar, wind or battery storage
- Campuses and commercial buildings
- Groups reporting energy for ESG
Before and after
What changes
The same job, today and with Ilonnati.
- Today: Energy arrives as a monthly bill for the whole site. With Ilonnati: Energy is measured by source and by panel as it is used, every day of the month.
- Today: Solar, generator and grid are read on separate meters, if at all. With Ilonnati: Grid, solar, wind, battery and generator supply are shown together in one view.
- Today: An overloaded feeder or a voltage dip is found when equipment trips. With Ilonnati: LT panel readings flag overcurrent and voltage deviation as they happen.
- Today: Nobody can say what a tonne of product cost in power. With Ilonnati: Energy is set against output, by division and machine, to give energy per unit produced.
- Today: A rising load is noticed months later, on the bill. With Ilonnati: A policy alert fires when a threshold is crossed or a trend drifts from its usual course.
How it works
From the reading in the field to the action on the screen, and back.
- 01
Meters at the sources
Supply from the grid, solar, wind, battery storage and the generators is measured where it enters the site.
- 02
Down to the panels
Each LT panel reports voltage, current and power quality, and the larger machines are metered on their own.
- 03
Set against output
Energy by division and by machine is set against production, to give the energy used per unit produced.
- 04
Policies for alerts
The team sets the rules: a panel over its current limit, a voltage outside its band, a machine’s use climbing week on week.
- 05
An alert is followed up
A compressor’s daily use climbs while output stays flat; the alert goes to its engineer, who checks it at the next stop.
- 06
The monthly review
Reports by source, division and machine show where the energy went and what each unit of output cost in power.
What is measured
Each reading reaches IoTyX through the Ilonnati controller beside the equipment.
| Reading | What it tells you |
|---|---|
| Supply by source | How much came from the grid, solar, wind, battery storage and the generators |
| Voltage | Deviation from the supply’s band, before it trips or damages equipment |
| Current | Overcurrent on a panel or feeder, as it happens |
| Power quality | Disturbances on the supply that heat motors and trip sensitive equipment |
| Energy per machine | Which machines use the most, and which draw more than their rating suggests |
| Energy per unit produced | What each unit of output cost in power, by division and over time |
| Battery state | Status and health of battery banks, so a weak bank is found before it is needed |
The rules and programmes behind it
Public programmes and rules that ask for this kind of measurement. Each links to the body that publishes it.
1,333
Under the PAT scheme, 1,333 large energy users in 13 sectors have energy-saving targets; in 2022–23 they saved 25.77 million tonnes of oil equivalent.
PAT scheme, PIB, Ministry of Power, 29 July 2024100 kW
The Energy Conservation Building Code applies to buildings with a connected load of 100 kW or a contract demand of 120 kVA or more, and asks larger ones to meter HVAC, lighting and other services separately.
ECBC 2017, as notified by Uttar Pradesh, 2018
Industries where it applies
Each industry page sets out its equipment, its rules and the other use cases that run there.
Questions buyers ask
Ask about your own network, plant or campus. An engineer will reply.
Contact us01Which sources of power can it measure?
Grid supply, solar, wind, battery storage and backup generators, shown together, so the whole energy supply of a site is in one view.
02What is monitored at the LT panels?
Real-time readings from each low-tension panel, for overcurrent detection, voltage deviation and power quality analysis.
03Can it show specific energy consumption?
Yes. Energy is measured by machine and by division and set against production, to give the energy used per unit of product.
04How are alerts set?
By policy. The team configures alerts for a threshold that is crossed and for a trend that moves away from its usual course, and each alert goes to the people responsible.